The message below is output when a heartbeat abnormality is detected during heartbeat monitoring of operating systems or servers:
detected an error on the monitored object "server(server identifier name)": no response:ping timeout (MCA00019)
If the heartbeat_error_action parameter in serverIdentifier.conf is set to "message", even if automatic switch/disconnection is enabled and Mirroring Controller is started, automatic switch/disconnection is not performed when a heartbeat abnormality is detected. Therefore, user action will be necessary.
This section explains the action required when the heartbeat_error_action parameter is set to "message" and a heartbeat abnormality is detected.
Identify the cause of the heartbeat abnormality. The possible causes are below:
The remote operating system or server crashed or is unresponsive
An admin network issue occurred
Address the cause identified in step 1.
The remote operating system or server crashed or is unresponsive
Manually perform switch or disconnection using the mc_ctl command.
An admin network issue occurred
Refer to "Chapter 4 Action Required when an Error Occurs in Database Multiplexing Mode", and recover the database multiplexing system.